Skip to main content

Table 3 Paired t-test analysis of thromboelastography (TEG) values derived from pre-operative and post-reperfusion (paired) samples in renal transplant patients (n = 8)

From: The feasibility and applications of non-invasive cardiac output monitoring, thromboelastography and transit-time flow measurement in living-related renal transplantation surgery: results of a prospective pilot observational study

  Pre-operative samples (value, 95% CI) Post-reperfusion samples (value, 95% CI) Paired t-test P value
Reaction time (R; min) 7.0 (6.3-7.8) 6.4 (5.9-6.9) 0.07
Kinetic time (K; min) 2.10 (1.5-2.7) 2.16 (1.8-2.6) 0.84
Alpha angle (degrees) 62.4 (56.6-68.2) 59.5 (52.2-66.8) 0.71
Maximum amplitude (MA; mm) 67.4 (61.3-73.6) 65.3 (57.9-72.7) 0.98
G-value 11.3 (8.3-14.3) 10.4 (6.6-14.2) 0.84
LY30 (%) 1.0 (0.29-1.71) 0.33 (0.15-0.80) 0.02
LY60 (%) 3.6 (1.7-5.5) 2.0 (0.5-3.5) 0.02
Amplitude (A; mm) 61.8 (54.4-69.3) 61.6 (53.3-69.8) 0.45
Coagulation index (CI) -0.16 (-1.9-1.59) -0.25 (-1.7-1.1) 0.52